Home › Brands › Alpha

Alpha Boilers

Alpha boilers explained, and how to find a Greater Manchester engineer who works on them.

Find an accredited installerBoiler broken down?
  • Check any engineer’s Gas Safe registration before work starts
  • Current & older Alpha models
  • All 10 Greater Manchester boroughs
New combi boilers typically from £1,800 fitted, like for like
Boiler servicing £80–£120 · Repairs from £120
Current boilers
E-Tec Plus NX, E-Tec NX, Evoke NX, E-Tec NXS & E-Tec Regular
Older models
InTec, InTec2, CD & Eco ranges
Part of
Immergas Group
Heating since
1966
Area
Greater Manchester

Finding an engineer for an Alpha boiler

No Greater Manchester firm lists Alpha among its makes yet, but most boiler engineers work on all the main makes. Compare firms by the job you need:

Alpha boilers

Alpha repairs, servicing & installation

Alpha ranges

Alpha boilers by type

Alpha’s current boilers cover combi, system and regular set-ups. Current NX models use a stainless steel heat exchanger coil moulded in a composite thermoplastic casing, which makes the boiler lighter to lift. The exact model and output are on the boiler’s data badge and in its manual, which matters for fault codes, parts and pressure settings.

Combi boilers

Heating and hot water on demand with no cylinder. The current combis are the E-Tec Plus NX (28, 33 and 38), the E-Tec NX (28 and 33) and the Evoke NX (28 and 33). Combis are generally best suited to smaller homes, particularly those with one bathroom.

System boilers

The E-Tec NXS system boiler comes in 20, 30 and 35 models. It works with a hot water cylinder but doesn’t need a cold water tank in the loft, which can be better suited to homes with more than one bathroom or higher hot water demand.

Regular boilers

The E-Tec Regular is a heat-only boiler for open-vented systems, or sealed systems with Alpha’s sealed system kit. At 600 × 390 × 305mm it is compact, every model is a one-person lift, and it can suit homes replacing an old cast-iron boiler while keeping the cylinder.

LPG versions of the E-Tec NX, Evoke NX and E-Tec NXS are available, but not every model or output comes in LPG, so check the data badge or manual for your boiler, and have any LPG work done by a suitably qualified Gas Safe registered engineer. Alpha also makes the E-Tec Hybrid boiler and heat pump package and the Alpha Hydro air source heat pump. If you’re thinking about moving away from gas, see our heat pumps page.

Local know-how

Alpha boilers in Greater Manchester homes

Terraces, semis & flats

In the terraces and semis of Reddish, Droylsden, Failsworth and Walkden, and in flats around Wythenshawe, the boiler is often a combi in a kitchen cupboard. If an older Alpha combi is near the end of its life, a like-for-like combi swap may be a straightforward replacement, depending on the home’s heating and hot water needs.

Homes with a cylinder

Larger houses in places like Cheadle, Gatley, Uppermill and Prestwich may have two bathrooms and a hot water cylinder. Where the home already has a cylinder, a system boiler such as the E-Tec NXS or a heat-only boiler such as the E-Tec Regular may be better suited than switching to a combi.

Soft water, but sludge still matters

United Utilities says most water in the North West is naturally soft, so limescale is less of a worry than in hard-water areas. Sludge and debris can still build up, and Alpha’s guarantee covers the boiler, not the wider system, so inhibitor levels and a magnetic filter are worth checking at every service.

Fault codes

Common Alpha fault codes

Current Alpha boilers show an error code on the display when something is wrong. The codes below are from Alpha’s installation and servicing instructions for the E-Tec 28NX and 33NX combis. Codes can vary by model, older Alpha boilers may use different codes or indicator lights, and a code can have more than one cause, so check the manual for your boiler, which for current models can be downloaded from each boiler’s product page on Alpha’s website. Follow your boiler manual when restarting or repressurising, and never open the boiler casing or inspect or touch the flue yourself: anything beyond a restart, checking the gas supply or topping up the pressure is a job for a Gas Safe registered engineer.

CodeWhat it can indicateWhat you can do
E01Ignition failure: no flame was detected during the ignition sequence. It can be associated with the gas supply, the ignition or sensing electrode, or the gas valve.Check your other gas appliances work and the meter has credit, then restart once as your manual describes. If it comes back, call an engineer.
E02Overheat lockout: the overheat sensor has activated. This can indicate restricted flow, air in the system or a pump problem.Check the pressure and that radiator valves are open. If it locks out again, call an engineer.
E03High flue temperature: the flue sensor has detected flue gases that are too hot.Don’t touch the flue. This needs a Gas Safe registered engineer.
E08The maximum number of resets has been reached.Stop resetting the boiler and call an engineer to find the underlying fault.
E10Low primary system pressure: the pressure switch has operated. Causes can include a leak, the expansion vessel or the pressure relief valve.If you’re confident doing it, top up using the filling loop as your manual describes. If the pressure keeps dropping, call an engineer.
E16A fan fault, or a problem with the fan wiring.This needs a Gas Safe registered engineer.

These codes are given as a guide only. Codes can vary by model, so always check the code for your exact boiler on Alpha’s customer support pages or in your boiler manual.

Low pressure is one of the first things to check if the heating stops. Alpha’s guidance is that a reading of around 1 to 1.5 bar generally suggests normal function, below 1 bar usually indicates a problem, and the correct figure can vary by model, so check the boiler manual before repressurising. If the pressure keeps dropping, have the system checked for a leak or other fault by a Gas Safe registered engineer. Our guide to a boiler losing pressure covers the checks you can make first, and in freezing weather it’s worth knowing how to thaw a frozen condensate pipe.

If you smell gas, don’t reset the boiler, use electrical switches or light a flame. Turn off the gas at the meter if it’s safe to, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999 from outside.

Guarantee & servicing

Alpha warranties explained

Alpha’s warranty lengths vary by model and by what is fitted with the boiler. The E-Tec Plus NX has a 10-year standard warranty, which rises to 11 years with Alpha’s Cyclone Plus NX magnetic filter or 13 years with the PremierPack Pro, subject to Alpha’s terms. The E-Tec NX, Evoke NX, E-Tec NXS and E-Tec Regular have a 7-year standard warranty, and on some models fitting Alpha accessories such as the Cyclone filter or PremierPack Pro can extend it. Always check the terms for the exact model and installation.

01

Register it promptly

Alpha’s installation instructions for the E-Tec NX say the boiler must be registered with Alpha within one month of installation for the guarantee to start. Conditions can vary by model, so register promptly, keep the confirmation and check Alpha’s current terms. If your boiler might still be under warranty, check with the installer or with Alpha before booking a repair.

02

Serviced every year

To keep the guarantee, the boiler needs an annual service by a Gas Safe registered engineer. Keep the service record in the Benchmark logbook.

03

The boiler, not the system

Alpha’s warranty covers the appliance only, not radiators, pipework, valves, taps or showers. If sludge from the heating system gets into a new boiler and damages it, the warranty can be void, which is why system cleaning and a filter matter when a boiler is fitted.

Controls

Alpha heating controls

Good controls help any boiler run more efficiently and cost less to run. Current Alpha NX boilers are compatible with OpenTherm and Alpha BUS controls and with weather compensation, and a heating engineer can check what your boiler will accept before you upgrade.

Alpha Touch

A wireless Wi-Fi thermostat controlled through the Alpha Touch app on iOS and Android, with geolocation, optimised start and a holiday mode. It is OpenTherm compatible and Boiler Plus compliant.

Climatic & EasyStat

Alpha’s Climatic controls come in RF (wireless) and hard-wired versions, alongside the Digital EasyStat. Which controls suit depends on the boiler model and whether it’s a combi or system boiler.

Weather compensation

Current NX boilers can take a simple external sensor, so the boiler adjusts its flow temperature to the weather outside. Lower flow temperatures can help a condensing boiler run more efficiently.

Repair or replace?

Is it worth repairing an older Alpha?

Often, yes. Many faults come down to a single part such as a fan, sensor or ignition electrode. Parts availability varies for older models, so an engineer will confirm the part before quoting. It may be worth comparing a new boiler installation when the boiler is more than 10 to 15 years old, boiler repairs are becoming frequent, or a major part such as the heat exchanger has failed.

Other brands

Not an Alpha?

Repairs, servicing and replacements for all the main makes, including Worcester Bosch, Vaillant, Baxi, Ideal, Viessmann, Glow-worm, Potterton and Intergas.

All brands →

FAQs

Alpha boiler questions

Who makes Alpha boilers?

Alpha has been making heating products since 1966 and has its UK head office in Kent. It is part of the Immergas Group, a family-owned heating manufacturer based in Brescello, Italy. Alpha’s current gas boilers are the E-Tec Plus NX, E-Tec NX and Evoke NX combis, the E-Tec NXS system boiler and the E-Tec Regular.

Can an older Alpha boiler still be repaired?

Often, yes. Many faults come down to a single part such as a fan, sensor or ignition electrode. Parts availability varies for older models such as the InTec and CD ranges, so a Gas Safe registered engineer will diagnose the fault and confirm the part before quoting. If the boiler is more than 10 to 15 years old or faults are frequent, it may be worth comparing the cost of a new boiler.

What does E10 mean on an Alpha boiler?

On the Alpha E-Tec 28NX and 33NX, E10 means the primary system pressure is low and the pressure switch has operated. Causes can include a leak, the expansion vessel or the pressure relief valve. You can top up the pressure using the filling loop as your manual describes, but codes can vary by model and have more than one cause, so check the code for your exact model on Alpha’s website or in your boiler manual. If the pressure keeps dropping, have a Gas Safe registered engineer check the system.

What pressure should an Alpha boiler be at?

Alpha’s guidance is that a reading of around 1 to 1.5 bar generally suggests normal function, and below 1 bar usually indicates a problem. The correct pressure can vary by model, so check your boiler manual before topping up. On some older Alpha boilers with indicator lights, the A and B lights flashing alternately means the system pressure is too low.

How long is the Alpha boiler warranty?

It depends on the model and what is fitted with it. The E-Tec Plus NX has a 10-year standard warranty, rising to 11 years with Alpha’s Cyclone Plus NX filter or 13 years with the PremierPack Pro. The E-Tec NX, Evoke NX, E-Tec NXS and E-Tec Regular have a 7-year standard warranty. Alpha’s E-Tec NX instructions say the boiler must be registered within one month of installation and serviced every year by a Gas Safe registered engineer. Conditions can vary by model, so check Alpha’s current terms for your exact boiler.

Does the Alpha warranty cover my radiators and pipework?

No. Alpha’s boiler warranty covers the appliance only, not the central heating or hot water system, such as radiators, pipework, valves, taps or showers. If sludge from the system damages the boiler, the warranty can be void, so a clean system, inhibitor and a magnetic filter are important.

Run a heating firm in Greater Manchester?

You may already be listed. Claim this free profile to add your website link, photos and the jobs you do.

Claim your profileFind a heating engineer