Home › Brands › Intergas

Intergas Boilers

Intergas boilers explained, and how to find a Greater Manchester engineer who works on them.

Find an accredited installerBoiler broken down?
  • Check any engineer’s Gas Safe registration before work starts
  • Combi & heat-only Intergas models
  • All 10 Greater Manchester boroughs
New combi boilers typically from £1,800 fitted, like for like
Boiler servicing £80–£120 · Repairs from £120
Combi boilers
Xtreme, Xclusive, ECO RF, HRE, Rapid & Rapid Plus
Heat-only boilers
HRE SB (sealed system) & HRE OV (open vent)
Part of
Rheem, since 2019
Making products for the home since
1939
Area
Greater Manchester

Accredited Intergas installers

2 firms in Greater Manchester list Intergas among the makes they work on. Most boiler engineers work on all the main makes, so the firms below are worth a call too.

Manchester (1 firm)

  1. Genie's Plumbing & Heating Experts

    4.9 (60 Google reviews)

    Central Heating Service · No public address, covers Manchester

    Accredited installer for: Worcester Bosch, Glow-worm, Intergas, Viessmann, Baxi

    New boilersBoiler repairsLandlord gas safetyHeating controlsUnderfloor heating installationEmergency callouts

    Describes itself as Gas Safe registered.

Stockport (1 firm)

  1. Hulme hall heating services

    5.0 (2 Google reviews)

    Central Heating Service · Based in Offerton & Davenport SK2

    Accredited installer for: Vaillant, Worcester Bosch, Viessmann, Intergas

    New boilersBoiler repairsBoiler servicingLandlord gas safety

    Describes itself as Gas Safe registered.

Firms are listed here if Intergas’s own installer finder lists them or they show its accreditation on their own website. Ratings and review counts are from Google, checked November 2026. Any paid featured listing is clearly labelled. We don’t check registrations or the quality of anyone’s work, so always check an engineer’s registration yourself and get a written quote before work starts.

Other boiler firms

Most engineers work on several makes. Compare firms by the job you need:

Intergas boilers

Intergas repairs, servicing & installation

Intergas ranges

Intergas boilers by type

Intergas is best known for combi boilers, but it also makes heat-only boilers for homes with a hot water cylinder. Its bithermic heat exchanger is an aluminium block with two separate copper circuits, one for heating and one for hot water, so Intergas combis don’t need a diverter valve or a separate plate heat exchanger. The exact model and output are on the data plate on the bottom of the boiler, which matters for fault codes, parts and pressure settings.

Combi boilers

Heating and hot water on demand with no cylinder. The current combis are the Xtreme, with built-in passive flue gas heat recovery, the Xclusive, with a touchscreen panel and RF module fitted as standard, the ECO RF, the HRE and the entry-level Rapid and Rapid Plus. Outputs and model names vary by range, so check the data plate.

Heat-only boilers

The HRE SB is a central-heating-only system boiler for sealed systems, and the HRE OV is designed for open-vented systems with a header tank, which can make it a like-for-like option for an older open-vent boiler. Both can heat a hot water cylinder as well as the radiators.

Convertible Rapid models

The Rapid and Rapid Plus can be set up by the installer as a combi, system or open-vent boiler, among other configurations, through the boiler’s parameter settings. The Rapid’s aluminium and steel flue meets the EN 13501-1 A1 fire classification, so it can be fitted on the external walls of buildings over 18 metres high.

An LPG conversion is listed for the Rapid. For other models, check the data plate or manual, and have any LPG work done by a suitably qualified Gas Safe registered engineer. Intergas also makes the Xtend hybrid systems, which pair a boiler with an air source heat pump, the Xceed air source heat pump and Xylinders hot water cylinders. If you’re thinking about moving away from gas, see our heat pumps page.

Local know-how

Intergas boilers in Greater Manchester homes

Terraces, semis & flats

In the terraces and semis of Openshaw, Clayton, Irlam and Atherton, the boiler is often a combi in a kitchen cupboard, and in city-centre apartment blocks it may be on an outside wall high above the street. If an older Intergas combi is near the end of its life, a like-for-like combi swap may be a straightforward replacement, depending on the home’s heating and hot water needs and the flue position.

Homes with a cylinder

Larger houses in places like Heald Green, Marple Bridge, Greenfield and Sale may have two bathrooms and a hot water cylinder, and some still have a header tank in the loft. Where the home already has a cylinder, a heat-only boiler such as the HRE SB or HRE OV may be better suited than switching to a combi.

Soft water, but sludge still matters

United Utilities says most water in the North West is naturally soft, so limescale is less of a worry than in hard-water areas. Sludge and debris can still build up, and Intergas’s warranty terms require the system to be cleaned and treated to BS 7593:2019, so inhibitor levels and a filter are worth checking at every service.

Fault codes

Common Intergas fault codes

When an Intergas boiler detects a fault, the red fault light above the reset button flashes and a code appears on the display. The codes below are from Intergas’s installation and operating instructions for the ECO RF combi. Codes can vary by model, the touchscreen Xclusive and Xtreme may show them differently, and a code can have more than one cause, so check the manual for your boiler, which can be downloaded from the documentation page for each model on Intergas’s website. Follow your boiler manual when restarting or repressurising, and never open the boiler casing or inspect or touch the flue yourself: anything beyond a restart, checking the gas supply or topping up the pressure is a job for a Gas Safe registered engineer.

CodeWhat it can indicateWhat you can do
0.0Low pressure in the central heating system. It can also be associated with a blocked pressure sensor.If you’re confident doing it, top up using the filling loop as your manual describes. If you need to top up more than a few times a year, call an engineer, as there is probably a leak.
1The boiler is getting too hot because there isn’t enough flow. Causes can include air in the system, closed radiator or isolation valves, or the pump not running.Check radiator valves are open and the pressure is correct. If it comes back, call an engineer.
4No flame signal: the burner hasn’t lit. It can be associated with the gas supply, the ignition or the gas valve.Check your other gas appliances work and the meter has credit, then press reset once. If it comes back, call an engineer.
5A poor flame signal. One of the possible causes is a blocked condensate drain.In freezing weather, check the condensate pipe. Otherwise this needs a Gas Safe registered engineer.
8Incorrect fan speed, which can point to the fan or its wiring.This needs a Gas Safe registered engineer.
10–14A fault with temperature sensor S1. Causes can include air in the boiler, the hot water flow sensor or the sensor wiring.This needs a Gas Safe registered engineer.

These codes are given as a guide only. Codes can vary by model, so always check the code for your exact boiler on Intergas’s customer service pages or in your boiler manual.

Low pressure is one of the first things to check if the heating stops. Intergas’s operating instructions for the ECO RF say the pressure should be between 1 and 2 bar when the system is cold. The figure can vary by model, so check your own boiler manual before topping up. If the pressure keeps dropping, have the system checked for a leak or other fault by a Gas Safe registered engineer. Our guide to a boiler losing pressure covers the checks you can make first, and in freezing weather it’s worth knowing how to thaw a frozen condensate pipe.

If you smell gas, don’t reset the boiler, use electrical switches or light a flame. Turn off the gas at the meter if it’s safe to, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999 from outside.

Guarantee & servicing

Intergas warranties explained

Intergas’s warranty lengths vary by model. The Xtreme, Xclusive and ECO RF have 10-year parts and labour warranties, the HRE range has 7 years, the Rapid Plus has 6 to 7 years and the entry-level Rapid has 3 years. The heat exchanger is covered for 10 years on every model except the Rapid, where it is 7 years. Intergas adds two more years when an Intergas System Filter is fitted with the boiler, subject to its terms. Always check the terms for the exact model and installation.

01

Register it within 30 days

The warranty has to be registered with Intergas within 30 days of installation, by the installer or the homeowner, and the installer must complete the Benchmark commissioning checklist. If these conditions aren’t met, the warranty is limited to 12 months. If your boiler might still be under warranty, check with the installer or with Intergas before booking a repair.

02

Serviced every year

To keep the warranty, the boiler needs an annual service by a Gas Safe registered engineer in line with Intergas’s instructions, with the details recorded in the Benchmark checklist or other proof of service kept.

03

The boiler, not the system

Intergas’s warranty covers boiler component failures only, not the connected system or accessories such as thermostats, time switches, motorised valves or external pumps. The terms also require the system to be flushed and treated to BS 7593:2019, and a failure caused by contaminated system water makes the engineer’s visit chargeable.

Controls

Intergas heating controls

Good controls help any boiler run more efficiently and cost less to run. Which controls suit depends on the Intergas model, so a heating engineer can check what your boiler will accept before you upgrade.

Comfort Touch

Intergas’s Comfort Touch thermostat, and the Comfort Touch app, which turns a smartphone into a smart thermostat. The Xclusive has the RF module needed for the app fitted as standard. The ECO RF has a built-in RF module too, with a gateway needed for remote access.

OpenTherm

The Xclusive and Xtreme have dual OpenTherm inputs and the Rapid is OpenTherm ready, so they can work with compatible modulating thermostats. Every Intergas boiler also works with standard on/off and programmable room thermostats.

Built-in timers & older apps

The Rapid has a built-in programmer. Intergas’s older Intouch app has been discontinued, so if you still use it, it’s worth asking about Comfort Touch or another compatible control at your next service.

Repair or replace?

Is it worth repairing an older Intergas?

Often, yes. Many faults come down to a single part such as a sensor, fan or ignition electrode, and Intergas combis have no diverter valve to wear out. Parts availability varies for older models, so an engineer will confirm the part before quoting. It may be worth comparing a new boiler installation when the boiler is more than 10 to 15 years old, boiler repairs are becoming frequent, or a major part such as the heat exchanger has failed. Our guide to how long boilers last covers the signs to look for.

Other brands

Not an Intergas?

Repairs, servicing and replacements for all the main makes, including Worcester Bosch, Vaillant, Baxi, Ideal, Viessmann, Glow-worm, Potterton and Alpha.

All brands →

FAQs

Intergas boiler questions

Who makes Intergas boilers?

Intergas has been making products for the home since 1939 and began developing high-efficiency condensing boilers in the Netherlands. It opened its UK head office in the Midlands in 2008 and has been part of the American manufacturer Rheem since 2019. Its current boilers are the Xtreme, Xclusive, ECO RF, HRE, Rapid and Rapid Plus combis, and the HRE SB and HRE OV heat-only boilers.

Does Intergas make system and regular boilers?

Yes. The HRE SB is a central-heating-only system boiler for sealed systems, and the HRE OV is designed for open-vented systems with a header tank. Both can heat a hot water cylinder. The Rapid and Rapid Plus can also be set up by the installer as a system or open-vent boiler through the parameter settings.

What does 0.0 mean on an Intergas boiler?

On the Intergas ECO RF, 0.0 on the display indicates low pressure in the central heating system, and it can also be associated with a blocked pressure sensor. You can top up using the filling loop as your manual describes, but codes can vary by model and have more than one cause, so check the code for your exact boiler on Intergas’s website or in your boiler manual. If you need to top up more than a few times a year, have a Gas Safe registered engineer check the system for a leak.

What pressure should an Intergas boiler be at?

Intergas’s operating instructions for the ECO RF say the central heating pressure should be between 1 and 2 bar when the system is cold. The correct figure can vary by model, so check your boiler manual before topping up.

How long is the Intergas boiler warranty?

It depends on the model. The Xtreme, Xclusive and ECO RF have 10-year parts and labour warranties, the HRE range 7 years, the Rapid Plus 6 to 7 years and the Rapid 3 years, and fitting an Intergas System Filter adds two years, subject to Intergas’s terms. The warranty must be registered within 30 days of installation, with the Benchmark checklist completed and the boiler serviced every year by a Gas Safe registered engineer, or it is limited to 12 months. Always check Intergas’s current terms for your exact boiler.

Does the Intergas warranty cover my thermostat and radiators?

No. Intergas’s warranty covers boiler component failures only, not the connected system or accessories such as thermostats, time switches, motorised valves or external pumps. If a failure is caused by contaminated water in the system, the engineer’s visit becomes chargeable, so a clean system, inhibitor and a filter are important.

Run a heating firm in Greater Manchester?

You may already be listed. Claim this free profile to add your website link, photos and the jobs you do.

Claim your profileFind a heating engineer